Skip to content
DEWETRON Customer Care Center

ORION series

 
belongs to: Discontinued Systems
DEWE-ORION Brochure
PDF1.10 MB
dewetron_dewe-orion_e.pdf
md5: 4717b031c373d77444c848c54bedfb08
English
DEWE-ORION-0424-200 Technical reference manual
PDF5.47 MB
dewe-orion-0424-200_105ex.pdf
md5: 76a0bb08f285e6038d854e54abd665fa
1.0.5
DEWE-ORION-0816-100x Technical Reference Manual
PDF2.51 MB
dewe-orion-0816-100x_techref_207e.pdf
md5: 34a67931a0e8c7e700617fb65ba991cf
2.0.7
Language: english
DEWE-ORION-0816-5M/10 Technical Reference Manual
PDF2.14 MB
dewe-orion-0816-5m_10m_techref_102e.pdf
md5: 23dc974f8cf25e5be0121bf38df0f63c
1.0.2
Language: english
DEWE-ORION-0824-20x Technical reference manual
PDF8.32 MB
dewe-orion-0824-20x_112ex.pdf
md5: 68e7acae70fa7722dc54e0a61973542d
1.1.2
DEWE-ORION-1616-100x Technical reference manual
PDF8.24 MB
dewe-orion-1616-100x_techref_105ex.pdf
md5: 9012f7b1beb1795385866ab009c050bc
1.0.5
DEWE-ORION-1616-10x Technical reference manual
PDF7.43 MB
dewe-orion-1616-10x_techref_120ex.pdf
md5: 7ee5380a3908f8979b38e4f17593dd2c
1.2.0
DEWE-ORION-1616-50x Technical Reference Manual
PDF7.71 MB
dewetron_dewe-orion-1616-50x_ex.pdf
md5: dfd1bfec649f8a032a3e95a943f175cf
English
DEWE-ORION-1616-50x Technical Reference Manual
PDF7.71 MB
dewe-orion-1616-50x_techref_117ex.pdf
md5: dfd1bfec649f8a032a3e95a943f175cf
1.1.7
DEWE-ORION-1622-10x Technical Reference Manual
PDF8.00 MB
dewe-orion-1622-10x_108ex.pdf
md5: 3a1d6076810d167e85754de3bb66919d
1.0.8
DEWE-ORION-1624 Technical Reference Manual
PDF6.65 MB
dewe-orion-1624_techref_109ex.pdf
md5: 82b785c2ddbc42558a0b3bab00df55d8
1.0.9
DEWE-ORION-1624-20x Technical Reference Manual
PDF2.97 MB
dewe-orion-1624-20x_109e.pdf
md5: 43d3d7cd1852a665a014a3020ef91a82
1.0.9
Language: English
ORION-EXP-CNT6 Technical Reference Manual
PDF1.50 MB
orion-exp-cnt6_techref_101ex.pdf
md5: 248a9498f7bc1cbaaf9f702b2af6fc26
1.0.1
Orion Driver
ZIP644 KB
orion_driver_x86.zip
md5: 62b7fed7bfd17370854c05c6bdee95ab
DAQ: 1.0.0.90 / DSA: 3.0.0.79
OS Compatibility: Windows 2000, Windows XP | 32-bit
OrionDAQ_Driver_2.3.1.0
ZIP5.91 MB
DAQ-BOARDS_DRIVER_v2.3.1.0.zip
md5: a8523f4f09ac9e528c7a6894684850b4
2.3.1.0
OS Compatibility: Win7 32-bit/ 64-bit | Win10 64-bit
Notes for OrionDAQ_Driver_2.3.1.0

-------------------------------------------------------------------------------------------------------------

Release Notice ORION DAQ Driver v2.3.1.0

2018-07-13

 

* Version: 2.3.1.0

 

* Components:

** 32-bit DAQ driver 

** 64-bit DAQ driver

 

* New Features:

** supports Win10 64-bit systems (Winx64)

** supports Win7 32-/64-Bit systems

 

* Bugfixes:

** FW version number indication fixed for Orion 0816-1000N and Orion 1616-1000 (correct "101", wrong "901")

** ORION co-installer fixed to support Win10x64

** external clocking with DEWE-Clock fixed

 

* Known Limitation:

** At all times only one instance of the DAQ driver is allowed.

** Installing the driver without Administrator privileges will result in an incorrect installation

** When Orion 1616-50x, Orion 0816-100x or Orion 1616-100x are used in the system, the DMA buffer size has to be adjusted manually in order to support all channels of the cards. For the detailed descritpion please refer to <<Application_Note_64 Bit Driver.pdf>>

** Measurement start: If no CAN frames are received before the internal 24-bit counter overflows (~3 minutes @100 Hz), the overflow is not considered and the CAN timestamps are wrong. Workaround: add a CAN channel that always sends data.  (problem @ BOSCH, will be fixed for ORION and Oxygen, was already fixed for TRION, won´t be fixed for ORION and DS => DS issue)

OrionDSA_Driver_5.0.1.0
ZIP21.30 MB
DSA-BOARDS_DRIVER_v5.0.1.0.zip
md5: 6c897c016a0064a78479f476539bfb9f
5.0.1.0
OS Compatibility: Win7 32-bit/ 64-bit | Win10 64-bit
Notes for OrionDSA_Driver_5.0.1.0

-------------------------------------------------------------------------------------------------------------

Release Notice ORION DSA Driver v5.0.1.0

2018-07-13

 

* Version: 5.0.1.0

 

* Components:

** 32-bit DAQ driver 

** 64-bit DAQ driver

 

* New Features:

** supports Win10 64-bit systems (Winx64)

** supports Win7 32-/64-Bit systems

 

* Bugfixes:

** FW version number indication fixed for Orion 0816-1000N and Orion 1616-1000 (correct "101", wrong "901")

** ORION co-installer fixed to support Win10x64

** external clocking with DEWE-Clock fixed

 

* Known Limitation:

** At all times only one instance of the DAQ driver is allowed.

** Installing the driver without Administrator privileges will result in an incorrect installation

** Measurement start: If no CAN frames are received before the internal 24-bit counter overflows (~3 minutes @100 Hz), the overflow is not considered and the CAN timestamps are wrong. Workaround: add a CAN channel that always sends data.  (problem @ BOSCH, will be fixed for ORION and Oxygen, was already fixed for TRION, won´t be fixed for ORION and DS => DS issue)